Lab D-TagCLIA deficiency tags, decoded Book a free consultation
Home › T3 Uptake

T3 Uptake: CLIA Requirements Mapped to 42 CFR 493

T3 Uptake testing touches about eight CLIA standards, from test categorization (42 CFR 493.17) through QC (42 CFR 493.1256) and test reporting (42 CFR 493.1291). The table below maps each one to the T3 Uptake records to keep ready.

Last reviewed Nov 24, 2026 · By the Sound Lab Consultants regulatory team · Sources listed below

T3 Uptake requirement map

Use this map to find the regulation behind each T3 Uptake requirement. Survey deficiency tags in CMS Appendix C are organized around these same sections.

Requirement42 CFR 493What to keep on file for T3 Uptake
Test categorization (waived, moderate, high)42 CFR 493.17FDA categorization printout for your T3 Uptake test system
QC42 CFR 493.1256Daily T3 Uptake QC records, Levey-Jennings charts, corrective action log, control lot ranges
Calibration verification42 CFR 493.1255Six-month T3 Uptake calibration verification and reportable range data with director review
Proficiency testing42 CFR 493.801, Subpart HT3 Uptake PT enrollment, attestation statements, graded reports, investigation of every miss
Comparison of results across methods or sites42 CFR 493.1281Twice-yearly comparison if T3 Uptake runs on more than one instrument, method or site
Method verification42 CFR 493.1253T3 Uptake verification study: accuracy, precision, reportable range, reference interval check, director sign-off
Test report and critical values42 CFR 493.1291Critical value list, call log with read-back, report format showing T3 Uptake reference intervals
PersonnelSubpart MTraining and competency records for everyone who runs T3 Uptake

Proficiency testing

T3 Uptake is a regulated analyte (endocrinology, 42 CFR 493.933). CLIA PT acceptance limit: target value ±18%.

Quick audit questions

Related tests

Full guide: T3 Uptake testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.

For laboratory compliance and operations only, not medical advice or patient care guidance.

Have a D-tag to answer?

Sound Lab Consultants maps each D-tag on your CMS-2567 to the regulation and Appendix C guidance and helps you build a correction that holds.

Book a free consultation

Related guides on soundlabconsult.com:

Frequently asked questions

Which CLIA regulations apply to T3 Uptake?

Mainly 42 CFR 493.17 (categorization), Subpart H/I or 493.1236 (PT and accuracy), 493.1253 (verification), 493.1255 (calibration), 493.1256 (QC), 493.1281 (comparisons) and 493.1291 (reporting).

Does this page list D-tag numbers?

No. D-tags come from CMS Appendix C; this map points to the 42 CFR 493 sections those tags are based on so you can read the rule itself.

What does T3 Uptake PT require?

T3 Uptake is a regulated analyte (endocrinology, 42 CFR 493.933). CLIA PT acceptance limit: target value ±18%.

Sources

More on Lab D-Tag