Lab D-TagCLIA deficiency tags, decoded Book a free consultation
Home › Fibrinogen

Fibrinogen: CLIA Requirements Mapped to 42 CFR 493

Fibrinogen testing touches about eight CLIA standards, from test categorization (42 CFR 493.17) through QC (42 CFR 493.1256) and test reporting (42 CFR 493.1291). The table below maps each one to the Fibrinogen records to keep ready.

Last reviewed Nov 24, 2026 · By the Sound Lab Consultants regulatory team · Sources listed below

Fibrinogen requirement map

Use this map to find the regulation behind each Fibrinogen requirement. Survey deficiency tags in CMS Appendix C are organized around these same sections.

Requirement42 CFR 493What to keep on file for Fibrinogen
Test categorization (waived, moderate, high)42 CFR 493.17FDA categorization printout for your Fibrinogen test system
QC42 CFR 493.1256, 42 CFR 493.1269Daily Fibrinogen QC records, Levey-Jennings charts, corrective action log, control lot ranges
Calibration verification42 CFR 493.1255Six-month Fibrinogen calibration verification and reportable range data with director review
Proficiency testing42 CFR 493.801, Subpart HFibrinogen PT enrollment, attestation statements, graded reports, investigation of every miss
Comparison of results across methods or sites42 CFR 493.1281Twice-yearly comparison if Fibrinogen runs on more than one instrument, method or site
Method verification42 CFR 493.1253Fibrinogen verification study: accuracy, precision, reportable range, reference interval check, director sign-off
Test report and critical values42 CFR 493.1291Critical value list, call log with read-back, report format showing Fibrinogen reference intervals
PersonnelSubpart MTraining and competency records for everyone who runs Fibrinogen

Proficiency testing

Fibrinogen is a regulated analyte (hematology (coagulation), 42 CFR 493.941). CLIA PT acceptance limit: target ±20%.

Quick audit questions

Related tests

Full guide: Fibrinogen testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.

For laboratory compliance and operations only, not medical advice or patient care guidance.

Have a D-tag to answer?

Sound Lab Consultants maps each D-tag on your CMS-2567 to the regulation and Appendix C guidance and helps you build a correction that holds.

Book a free consultation

Related guides on soundlabconsult.com:

Frequently asked questions

Which CLIA regulations apply to Fibrinogen?

Mainly 42 CFR 493.17 (categorization), Subpart H/I or 493.1236 (PT and accuracy), 493.1253 (verification), 493.1255 (calibration), 493.1256 (QC), 493.1281 (comparisons) and 493.1291 (reporting).

Does this page list D-tag numbers?

No. D-tags come from CMS Appendix C; this map points to the 42 CFR 493 sections those tags are based on so you can read the rule itself.

What does Fibrinogen PT require?

Fibrinogen is a regulated analyte (hematology (coagulation), 42 CFR 493.941). CLIA PT acceptance limit: target ±20%.